The basic idea
Aluminium is strong, light and corrosion-resistant — but it conducts heat roughly 1,000 times better than air. A single solid aluminium frame is effectively a metal bridge carrying outdoor heat straight to the room side.
A thermal break interrupts that bridge. A narrow strip of polyamide (usually 14–34 mm wide) is mechanically rolled between the inner and outer aluminium profiles, so the two halves no longer touch. Heat has to cross a poor conductor instead of a continuous metal path.
Width is not the whole story
Buyers often compare only the number: 24 mm versus 34 mm. A wider strip generally helps, but the frame's overall U-value also depends on the glass, the spacer, the seal design and how the strip is positioned relative to the glazing.
Ask for the whole-window U-value, not the profile number. A well-designed 24 mm system with warm-edge spacers and double low-E glazing can outperform a poorly detailed 34 mm one.
Where projects actually lose performance
The weak points are rarely the middle of the profile. They are the corners, the hinge points, the drainage paths and the junction where the frame meets the wall. A continuous insulation line must survive all of these.
On site, we pay particular attention to the corner joints and to the seal continuity around the sash. These are the details that decide whether the number on the catalogue shows up in the building.
A practical specification question
When comparing quotes, ask the supplier for three things together: the whole-window U-value, the glass construction, and the thermal-break width with its polyamide grade. A supplier who can answer all three is usually the one who has actually engineered the system.